| Both sides previous revision Previous revision | |
| report:dvp [2026/05/21 12:15] – [7.4 Design] team5 | report:dvp [2026/05/28 10:05] (current) – [7.4 Design] team5 |
|---|
| <figure fig:fea_main_interior> | <figure fig:fea_main_interior> |
| {{ :report:main_box_front.png?direct&800 | FEA Main Box Internal Stress Map}} | {{ :report:main_box_front.png?direct&800 | FEA Main Box Internal Stress Map}} |
| <caption>Internal Von Mises stress distribution on the main ceiling-mounted PA Rail housing under a 100 N distributed load</caption> | <caption>Top View of Von Mises stress distribution on the main ceiling-mounted PA Rail housing under a 100 N distributed load</caption> |
| </figure> | </figure> |
| </WRAP> | </WRAP> |
| <figure fig:fea_main_exterior> | <figure fig:fea_main_exterior> |
| {{ :report:main_box_down.png?direct&800 | FEA Main Box External Stress Map}} | {{ :report:main_box_down.png?direct&800 | FEA Main Box External Stress Map}} |
| <caption>External view of the main housing Von Mises stress distribution around the central pole interface junction</caption> | <caption>Bottom view of the main housing Von Mises stress distribution around the central pole interface junction</caption> |
| </figure> | </figure> |
| </WRAP> | </WRAP> |
| <figure fig:fea_secondary_exterior> | <figure fig:fea_secondary_exterior> |
| {{ :report:pole_box_down.png?direct&800 | FEA Secondary Node Exterior Stress Map}} | {{ :report:pole_box_down.png?direct&800 | FEA Secondary Node Exterior Stress Map}} |
| <caption>Exterior Von Mises stress distribution on the pole-mounted secondary node showing stress paths around geometric features</caption> | <caption>Bottom View with Von Mises stress distribution on the pole-mounted secondary node showing stress paths around geometric features</caption> |
| </figure> | </figure> |
| </WRAP> | </WRAP> |
| <figure fig:fea_secondary_interior> | <figure fig:fea_secondary_interior> |
| {{ :report:pole_box_front.png?direct&800 | FEA Secondary Node Interior Stress Map}} | {{ :report:pole_box_front.png?direct&800 | FEA Secondary Node Interior Stress Map}} |
| <caption>Interior view of the secondary node simulation highlighting the stress isolation achieved inside the electronic casing compartment</caption> | <caption>Top view of the secondary node simulation highlighting the stress isolation achieved inside the electronic casing compartment</caption> |
| </figure> | </figure> |
| </WRAP> | </WRAP> |