report:dvp

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
report:dvp [2026/05/21 12:15] – [7.4 Design] team5report:dvp [2026/05/28 10:05] (current) – [7.4 Design] team5
Line 176: Line 176:
 <figure fig:fea_main_interior> <figure fig:fea_main_interior>
 {{ :report:main_box_front.png?direct&800 | FEA Main Box Internal Stress Map}} {{ :report:main_box_front.png?direct&800 | FEA Main Box Internal Stress Map}}
-<caption>Internal Von Mises stress distribution on the main ceiling-mounted PA Rail housing under a 100 N distributed load</caption>+<caption>Top View of Von Mises stress distribution on the main ceiling-mounted PA Rail housing under a 100 N distributed load</caption>
 </figure> </figure>
 </WRAP> </WRAP>
Line 183: Line 183:
 <figure fig:fea_main_exterior> <figure fig:fea_main_exterior>
 {{ :report:main_box_down.png?direct&800 | FEA Main Box External Stress Map}} {{ :report:main_box_down.png?direct&800 | FEA Main Box External Stress Map}}
-<caption>External view of the main housing Von Mises stress distribution around the central pole interface junction</caption>+<caption>Bottom view of the main housing Von Mises stress distribution around the central pole interface junction</caption>
 </figure> </figure>
 </WRAP> </WRAP>
Line 194: Line 194:
 <figure fig:fea_secondary_exterior> <figure fig:fea_secondary_exterior>
 {{ :report:pole_box_down.png?direct&800 | FEA Secondary Node Exterior Stress Map}} {{ :report:pole_box_down.png?direct&800 | FEA Secondary Node Exterior Stress Map}}
-<caption>Exterior Von Mises stress distribution on the pole-mounted secondary node showing stress paths around geometric features</caption>+<caption>Bottom View with Von Mises stress distribution on the pole-mounted secondary node showing stress paths around geometric features</caption>
 </figure> </figure>
 </WRAP> </WRAP>
Line 201: Line 201:
 <figure fig:fea_secondary_interior> <figure fig:fea_secondary_interior>
 {{ :report:pole_box_front.png?direct&800 | FEA Secondary Node Interior Stress Map}} {{ :report:pole_box_front.png?direct&800 | FEA Secondary Node Interior Stress Map}}
-<caption>Interior view of the secondary node simulation highlighting the stress isolation achieved inside the electronic casing compartment</caption>+<caption>Top view of the secondary node simulation highlighting the stress isolation achieved inside the electronic casing compartment</caption>
 </figure> </figure>
 </WRAP> </WRAP>
  • report/dvp.txt
  • Last modified: 2026/05/28 10:05
  • by team5